Circuit Breakers for Flaky OSINT Sources: Fail Fast, Recover Quietly

Some OSINT sources are up 99.9% of the time. Some are up 73%. Retrying a down source synchronously is how pipelines die. Circuit breakers turn a 30-second timeout into a 1-millisecond :circuit_open.

Tomáš Korcak (korczis) 349 words

A polite scraper hits a flaky source and waits 30 seconds for a TCP timeout. It does this 100 times an hour. That is 50 minutes of wall-clock time per hour spent waiting on one dead source. Meanwhile every other adapter is healthy and the dashboard looks fine. The fix is a circuit breaker, and in Elixir it is about 80 lines of GenServer wrapped around a few counters.

The three states

A circuit breaker is a tiny state machine:

  • closed — traffic flows, failures are counted.
  • open — traffic is rejected immediately with {:error, :circuit_open}.
  • half-open — one probe request is allowed; success closes, failure re-opens.

The trick is the transition rules. Too sensitive and you flap. Too tolerant and you are back to 50 minutes per hour of timeouts.

The rules that actually work

  • Open on: 5+ failures in a 30-second rolling window OR 3 consecutive failures.
  • Cool-down: exponential, starting at 10s, doubling up to 5 minutes.
  • Half-open probe: exactly one in-flight probe. Concurrent probes defeat the purpose.
  • Close on: probe success.
defmodule PrismaticOsint.Breaker do
  use GenServer

  def call(name, fun) do
    case GenServer.call(name, :state) do
      :open   -> {:error, :circuit_open}
      :closed -> record(name, safely(fun))
      :half_open -> probe(name, fun)
    end
  end

  defp safely(fun) do
    try do
      {:ok, fun.()}
    catch
      kind, reason -> {:error, {kind, reason}}
    end
  end
end

The try/catch wraps the user function so a crash never leaves the breaker in an inconsistent state. The :error path feeds the counter; the :ok path resets it.

Wire it into the pipeline

Every OSINT adapter gets wrapped at the boundary:

def search(query, opts) do
  Breaker.call(breaker_for(__MODULE__), fn ->
    HTTPoison.get!(url(query), [], recv_timeout: 5_000)
  end)
end

That is it. The adapter does not know about the breaker's internal state. The pipeline does not know about the adapter's flakiness. Both stay boring, which is the goal.

Telemetry is non-negotiable

Every state transition emits telemetry:

:telemetry.execute([:osint, :breaker, :open], %{count: 1}, %{adapter: name})
:telemetry.execute([:osint, :breaker, :half_open], %{count: 1}, %{adapter: name})
:telemetry.execute([:osint, :breaker, :closed], %{count: 1}, %{adapter: name})

A breaker that opens and never closes is a source that died. A breaker that flaps is a source with intermittent issues (and possibly a wrong cool-down). Without observability you cannot tell which is which.

Where to go next

Fail fast. Recover quietly. Let the healthy sources do the work.